Auto transom power unit installation instructions
1. Automobile tail plate power unit before installation must ensure that the oil cylinder hydraulic components, tubing and connectors to clean without any impurities.
2. The hydraulic oil viscosity should be 15-68 CST, should be clean without impurities, it is recommended to use N46 hydraulic oil.
3. The system USES the first 100 hours after the hydraulic oil should be changed, once every 3000 hours to replace the hydraulic oil in the future.
4. For the first time is up and running system, should immediately check whether sufficient amount of oil in the tank.
5. This power unit is suitable for horizontal installation.